Sub-Zero Compressor, Start Relay & Sealed-System Problems

Sub-Zero compressor clicking or not starting? Learn the difference between a failed start relay, compressor failure and refrigerant or sealed-system problems.

A Sub-Zero that clicks, hums, will not start or cannot cool does not automatically need a compressor. Start-device faults, electrical problems, refrigerant leaks and true compressor failures can create overlapping symptoms. The repair changes completely depending on which one is actually present.

Test the start system before condemning the compressor.

We verify supply voltage, relay/overload or start components and compressor electrical condition first. A failed start relay can look like a much more expensive compressor problem.

Sub-Zero compressor compartment during start relay diagnosis
Actual Sub-Zero compressor compartment. On this repair the compressor start relay had failed.

Start relay / overload failure

A bad start device can prevent the compressor from starting or cause repeated clicking. If the compressor itself tests correctly, replacing the failed start component can restore operation without opening the sealed refrigeration system.

True compressor failure

A compressor can fail electrically or mechanically. Diagnosis can involve winding checks, current draw, start behavior and refrigeration-system performance. A compressor that runs is not necessarily healthy, and a compressor that does not run is not necessarily failed.

Refrigerant leak

A leak can leave the compressor running while temperatures slowly rise. Oil residue, corrosion, pressure/temperature behavior and frost pattern can help locate the problem.

Corroded copper refrigerant tubing with a leak in a Sub-Zero sealed system
Actual corroded Sub-Zero refrigerant line that leaked the system charge.

What sealed-system repair involves

Depending on the failure, sealed-system work can include recovering refrigerant, repairing or replacing tubing, replacing a filter-drier, replacing a compressor, brazing connections, evacuating the system to remove air and moisture, charging the correct refrigerant amount and verifying temperatures and operating conditions afterward.

New Sub-Zero compressors and copper refrigeration tubing during installation
New compressors installed during an actual Sub-Zero sealed-system repair; the job is still in progress in this photo.

Why the filter-drier matters

When a refrigeration circuit is opened for major work, the filter-drier is part of protecting the sealed system from moisture and contamination. Proper evacuation and charging matter just as much as installing the new component.

Genuine replacement parts

Genuine Sub-Zero factory authorized compressor assembly box
Genuine Sub-Zero / factory-authorized compressor assembly used for the correct model.

We source genuine Sub-Zero / factory-authorized replacement components for these repairs. Model-specific fit and refrigeration specifications matter on built-in systems.

Sealed-system work is not a DIY repair.

Refrigerant handling, brazing, evacuation and charging require appropriate tools and procedures. The system should also be leak-tested and verified after the repair.

See Sub-Zero Repair for local service.